Velodyne DIGITAL DRIVE - REV G Istruzioni per gli Interventi Pagina 12

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 43
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 11
U
S
A
G
E
H
D
L
-
64
E
S2
and
S2.1
U
s
e
r
s
Ma nua
l
Available commands
The following run-time commands are available with the sensor:
Command Description Parameters
#HDLRPMnnnn$ Set spin rate from 300 to 1200 RPM nnnn is an integer between 0300 and 1200
n
flash memory (default is 600 RPM)
#HDLRPNnnnn$ Set spin rate from 300 to 1200 RPM nnn
n is an integer between 0300 and 1200
in RAM (default is 600 RPM)
#HDLIPAssssssssssssdddddddddddd$ Change source and/or destination • ssssssssssss is the source 12-digit IP address
IP addr
ess • dddddddddddd is the destination 12-digit
IP address
#HDLFOVsssnnn$ Change horizontal Field of View (HFOV) • sss = starting angle in degrees; sss is an integer
between 000 and 360
• nnn = ending angle in degrees; nnn is an
integer between 000 and 360
Y
ou can also upload calibration data from db.xml into
flash
memory
and
use
GPS
time
synchronization.
.
[ 9
]
Vedere la pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 42 43

Commenti su questo manuale

Nessun commento